![background image](http://html1.mh-extra.com/html/sames-kremlin/nanogun-airmix-h2o/nanogun-airmix-h2o_user-manual_3696968030.webp)
Index revision : A
30
7118
•
Step 4:
With the flat nose pliers, remove the
small PTFE tube surrounding the electrode.
Check that there are no residues in the pas-
sage of the electrode. If necessary, manu-
ally push a drill bit or a metal rod of 1 mm in
the hole.
Reassembly
:
The repair kit includes an electrode equipped
with its small PTFE tube.
•
Step 1:
Manually clean, if necessary with
caution, the passage of the electrode with
a drill bit or a metal rod of 1 mm in diame-
ter.
•
Step 2
: Insert the electrode with the PTFE
tube. As soon as it appears on the other
side of the head, pull it out with your fingers.
Then push it up to the bottom of the
housing using the screwdriver, and the
return strand of the electrode must go
back into a small bore, with only the rear
part of the electrode being flush with the
bottom of the counterbore.