7. Installation
WARNING : Before proceeding with any operation, please refer to the installation rules (
see §
2.2 page 7
).
With a piston pump for all versions
The paint intake must be installed within a ventilated zone.
The tank of paint must be a conductor and a capacity
≤
30 liters (8 US gal).
The dump hose end must be immersed in the paint.
WARNING : The paint supply pump:
• must feature a maximum ratio of 19:1 for the 120-bar version and of 30:1 for the
200-bar version;
• and the pump’s air inflow must be equipped with a safety relief valve to limit
pressure to a maximum value of 6.5 bar.
1
Nanogun Airmix H
2
O
gun
2
GNM 6080
control module
3
Piston pump
4
Insulating cabinet
5
Short circuiter
2
3
4
5
DES06789
1