Index revision : A
26
7118
WARNING : Prior to any maintenance operation carried out on the gun, please refer to the
health and safety instructions (
see § 2 page 7
):
- Turn off the the control module.
- Verify that the air and paint circuits are no longer pressurised.
- Dump the paint circuit.
10.2. Electro-pneumatic link
•
Step 1
: Disassemble the low-voltage cable
using a 3 Allen wrench, unscrew the two cap-
tive screws of the electro-pneumatic cou-
pling.
•
Step 2
: Disconnect the electro-pneumatic
coupling by pulling on it.
Step 1