SAMES KREMLIN
Page 11
Manual : 573.226.112
DESCRIPTION OF THE DEVICE
Ind.
Description
View from the top
View from the side
View from below
View from the side
1 Type plate
2 Reset button / reset
3 Control light that illuminates during the
heat-up phase. The control light goes
out when the set temperature is reached
and switches back on when heating up
is started again.
4 Thermostat with temperature scale from
30°C / 86°F to 85°C / 185°F
I = OFF
F = Anti-freeze function
5 Top with electrical switching and heating
elements
6 Air connection (G 1/4") (only for air
heating)
7 Bottom / heat exchanger
8 Connection for material hose - OUT
M 1/2 JIC for ID 9
M 3/4 JIC for ID 14 HV
9 24 V control voltage
10 Power connection (explosion protected
cable gland)
11 Grounding screw
12 Connection for material hose - IN
M 1/2 JIC for ID 9
M 3/4 JIC for ID 14 HV
13 Fastening screws for heat exchanger (M
8) Tightening torque: 1x 20 Nm + 1x 13
Nm
14 Seal openings when using for air
heating. Screws (M 10) are included in
the "Air heating" attachment kit.
15 Air connection (G 1/4") (only for air
heating)