SAMES KREMLIN
Page 15
Manual : 573.226.112
Observe the explosion protection zones
at your place of work.
In potentially explosive areas, the connection must be designed
explosion-protected. Cables and cable entries must be appropriately
approved and be temperature-resistant.
Entries that are not used must be sealed.
Cables and cable entries and the cables used must have at least a
maximum operating temperature of + 80°C / + 176° F Alternative,
equivalent approved cable entries may be used.
Assembly for 115 and 230 V devices
Assembly for 400 V devices
Installing the material fluid heater on a holder
The material fluid heater can be installed in different ways depending on the intended purpose:
on a holder directly on the frame of the spraying device or the coating unit,
separately on a wall holder.