GROUNDING THE DEVICE
To avoid risks caused by static electricity, the equipment as well as its
components must be grounded.
This wire must be connected to a safe ground.
- Connect the ground cable to the grounding screw provided for this. The grounding screw is
located next to the power cord connection and is labeled with
symbol.
- Attach the terminal of the ground cable to an electrically conductive object.
ATTACHING THE MATERIAL HOSES
- Remove yellow protective caps from the IN and OUT nozzles of the heat exchanger.
- Seal the delivered nipples well with medium thread lock.
- Install material hoses by means of double nipples to the material fluid heater (tightening torque 80
Nm).
Ind.
Description
8 Material outlet - OUT
M 1/2 JIC for ID 9
M 3/4 JIC for ID 14 HV
12 Material inlet - IN
M 1/2 JIC for ID 9
M 3/4 JIC for ID 14 HV