SAMES KREMLIN
Page 19
Manual : 573.226.112
Ind.
Description
1 Type plate
2 Reset button / reset
3 Control light illuminates during the
heat-up phase. The control light goes
out when the set temperature is
reached and switches back on when
heating up is started again.
4 Thermostat with temperature scale
from 30°C / 86°F to 85°C / 185°F
I = OFF
F = Anti-freeze function
When the outdoor temperature is below 10°C / 50°F, press the reset button and hold it until the
control light illuminates.
If the highest permissible temperature is exceeded, a temperature limiter switches the material fluid
heater off.
To switch it back on, press the reset button until the control light illuminates again.
FLUSHING
Flushing is necessary :
during the initial commissioning so that the spraying material is not influenced by the test
substance with which the equipment was tested in the factory for faultless function.
during a change of the material.
if the equipment is to be deactivated for a longer period.
WARNING!
Heating solvents can lead to an explosion.
Serious personal injuries and property damage may result.
Always flush and clean the device with a suitable cleaning fluid only in
cooled off
and voltage-free
condition!
NOTA :
Use the cleaning fluid pertaining to the new material and recommended by the
material manufacturer.
Observe and follow all work steps that are described in the operation manual of your
spraying device for a change of material and/or commissioning.