SAMES KREMLIN
Page 16
Manual : 573.226.112
Installing / disassembling top to / from bottom
The top and bottom of the material fluid heater can be twisted together in 90° steps, depending on
how the assembly situation onsite requires it.
Orientate yourself with the position of the material inlets and outlets to the position of the cable
gland when installing the top to the bottom.
Assembly when both the cable gland and the material inlets and outlets point to the same side is
not possible.
When installing the top and the bottom, always use the two holes that are located at the points
marked here.
Disassembly :
Despite relieving the pressure, residual pressures can still be present due to material congestion or
clumping which can suddenly escape during disassembly work and cause serious injuries.
You must be particularly careful during disassembly work.
When disassembling material hoses, cover the screw connection with a cloth in order to
catch possible material sprays.
- Disconnect device from power supply.
- Release both screws on the bottom of the device in order to lift the top from the bottom.
Installing the air heating
NOTA : A corresponding conversion kit is required for the air heating. Please
contact a Sames dealer or Sames customer service.
Use the spare parts list for the conversion kit as an aid for the installation.
Ind.
Description
45
L-plug-in connector
46
Cocket nipple
47
L-plug-in connector
48
Screw
If the material fluid heater is used for air heating for an air motor, proceed as follows:
- Install elbow union as air inlet in one of the holes on the bottom of the device.
- Screw pneumatic screw connection into the air outlet by means of the socket nipple.
- Establish a pneumatic connection between the air motor of the spraying device and the material
fluid heater.