Installation instructions
6.1
Connection to an energy optimisation unit (option)
D
When purchasing the "Connection energy optim
isation" option, the appliance is equipped by the
factory with the necessary interface (ABCD inter
face).
−
A = Appliance switched on
−
B = Appliance is heating
−
C = Requirement (energy optimisation unit)
−
D = Neutral conductor (N)
D
An energy optimisation unit may be connected
only by an electrical technician or the authorised
customer service.
D
Connection, see circuit diagram!
6.2
Connection to a load shedding unit
−
Load shedding units switch off the consumers in the event of power peaks.
−
In the event of switching off by the load shedding unit, the cooking chamber heating is switched off.
−
Thereby, heating-up and cooking processes currently being carried out are not taken into considera
tion.
Connection
D
A load shedding unit must only be connected by an electrical technician or the authorised customer
service.
Important:
−
For example, if the phases L2 and L3 are switched off by the load shedding unit, the fused power path
(fuse F4) must be reconnected to L1.
−
Observe the circuit diagram!
D
If connection to L1 is not correct, operation is not possible. An error message is emitted.
7. Initial
commissioning
.
Remove cartons, foils, accessories, grilles and containers from the cooking chamber.
.
Clean outside of the appliance.
.
Clean the cooking chamber.
D
If a heating process is not possible after transport in cold environments: The safety temperature limiter
cuts off at freezing temperatures. Once the safety temperature limiter has been sufficiently warmed
again from the room temperature, it activates itself automatically.
.
Before initial commissioning or after extended operating breaks, fill approx. 5 litres of water into the
cooking compartment drain (overheating protection/(odour trap).
Only for appliances with automatic cleaning system, not for Types 2011:
.
Before initial commissioning or after extended operating breaks, fill approx. 5 litres of water into the
cooking chamber drain (overheating protection/odour trap).
D
If no water is filled (fault number 4003), this results in destruction of the pumps in the drain system!
Description of cleaning process, see chapter in the operating instructions:
−
Connection of the cleaning‐ and rinse‐aid canisters for automatic cleaning (optional)
−
Cleaning the appliance and the cooking chamber
Circuit diagram example
PCB control assembly