Installation instructions
4.3
Connection of soft‐ and cold water
Risk of damage
The appliance may not be operated without water connection! A water connection is re
quired even if the appliance is only used for baking!
D
The connection requires using a pressure‐resist
ant flexible DVGW‐tested hose with a diameter of
at least 1/2 inch and union of 3/4 inch. Provide a
hose of adequate length to allow the appliance to
be moved during service tasks.
D
The appliance are factory‐equipped with a soft‐
and cold water connection. Use the connecting
piece only if you cannot provide separate water
supplies and the specifications for the cold and
soft‐water connections are ensured.
.
Rinse through the water pipes in the building sys
tem and supply hoses before connecting.
.
Connect the appliance to an easily accessible
water stopcock.
D
The supply hose may not be kinked or deformed!
.
Check that all connections are watertight.
Connection with connecting piece
The connecting piece may be used only if the water
corresponds to the requirements for soft water.
For requirements on the cold‐ and soft water connec
tion, see page 11 Chapter 4.2.4
Soft water
connection
Cold water
connection
623T, 611T, 1011T
611 QT, 1011QT, 2011QT
Soft water
connection
Cold water
connection
Dirt screen
item‐No. 249688
Connection
G3/4 inches
Dirt screen
item‐No. 249688
Connecting piece
Item No.: 878801
(cannot be used for
Type T)
Water connection
G3/4 inches
Sealing ring
(included in
connecting piece)