Installation instructions
6. Electrical
connection
DANGER! Electrical voltage!
Risk of electric shock that may result in serious injury or death! Installation,
service and repair tasks may only be carried out by authorised Customer Service.
D
If the appliance was transported in a cold environment, it must be stored at least for two hours in a
warm and dry room before making the electrical connection. This prevents condensation of moisture on
the electrical components and their subsequent damage.
D
Electrical connection must be carried out by a qualified electrician‐
−
according to the applicable VDE 0100 regulations and
−
the regulations of the power supply company concerned.
D
An electrical main switch must be installed upstream with easy access. The switch must effectively
disconnect the appliance at all poles from the mains. The contact opening must be at least 3 mm.
D
Instruct the owner and the operating personnel where the main switch provided in the kitchen for the
appliance is located so that the appliance may be switched off without danger in the event of hazards
to the user.
D
Install ground fault circuit interrupter for safety reasons.
D
Comply with the circuit diagram included with the
appliance!
D
Table units are supplied with a power cable as
series equipment. If the connecting cables must
be replaced, for example, due to the building
structure, a mains cable of the type H07RNF
according to VDEstandard must be used.
D
Observe the data on the type plate when making
the electrical connection.
The appliance must be connected to the equi
potential bonding system (earth connection). Its effi
ciency must be checked in accordance with
VDE0190.
Equipotential
bonding
Electrical
supply
cable
Electrical‐supply cable
623 T, 611T, 1011T
611QT, 1011QT, 2011QT
Equipotential bonding