035
AIS: No valid
ROT informa-
tion
No valid ROT
information
AIS NO ROT
Generated by: AIS Electronics Unit
Cause/Source: No data from external sensor
Reaction: The Electronics Unit continues operation.
Remedy: The telegrams ROT can not be received. Check
the sensor and the cabling; Check if the system that trans-
mits the data is working (RADARPILOT 1000); Check the
baud rate settings of the sensor inputs.
051
AIS: Channel
management
information not
accepted
Channel
management
not accepted
AIS SET
CHANNELS
Generated by: AIS Electronics Unit
Cause/Source: E.g. overlapping with an existing area
Reaction: The Electronics Unit continues operation.
Remedy: Check the channel management information.
052
AIS: GPS
receiver fault
GPS receiver
fault
AIS GPS
RECEIVER
Generated by: AIS Electronics Unit
Cause/Source: Internal GPS receiver malfunction
Reaction: The Electronics Unit continues operation without
internal GPS data and without direct GPS time synchroni-
zation.
Remedy: The Electronics Unit must be exchanged.
100
-
0100
-
Generated by: DCU, Internal Test
Error RAM Check
101
-
0101
-
Generated by: DCU, Internal Test
Error ROM Check
102
-
0102
-
Generated by: DCU, Internal Test
Error EEPROM number
103
-
0103
-
Generated by: DCU, Internal Test
MC system error (watchdog,...)
(104)
-
Target over-
flow
-
Generated by: DCU
See the Operating Instructions
(105)
-
Target display
overflow
-
Generated by: DCU
See the Operating Instructions
106
-
0106
-
Generated by: DCU, Internal Test
SIO pool empty
107
-
0107
-
Generated by: DCU, Internal Test
SIO FIFO overrun
108
-
0108
-
Generated by: DCU, Internal Test
Error while reading byte (RS422-1)
109
-
0109
-
Generated by: DCU, Internal Test
Error while writing byte (RS422-1)
110
-
0110
-
Generated by: DCU, Internal Test
Illegal size for message type (RS422-1)
111
-
0111
-
Generated by: DCU, Internal Test
Checksum error (RS422-1)
112
-
0112
-
Generated by: DCU, Internal Test
Error while reading byte (RS422-2)
Fault
Messages at
Error Message generated by,
Possible Cause/Source,