UAIS DEBEG 3400, Electronics Unit
ED3047G142 / 08 (2004-06)
Technical Manual
8 Fault Code List
t_ue_e09.fm / 21.06.04
78
113
-
0113
-
Generated by: DCU, Internal Test
Error while writing byte (RS422-2)
114
-
0114
-
Generated by: DCU, Internal Test
Illegal size for message type (RS422-2)
115
-
0115
-
Generated by: DCU, Internal Test
Checksum error (RS422-2)
116
-
0116
-
Generated by: DCU, Internal Test
Error while reading byte
117
-
0117
-
Generated by: DCU, Internal Test
Error while writing byte
118
-
0118
-
Generated by: DCU, Internal Test
Illegal size for message type
119
-
0119
-
Generated by: DCU, Internal Test
Checksum error
120
-
0120
-
Generated by: DCU, Internal Test
I
2
C bus error
(201)
-
Safety msg
transmission
failed
-
Generated by: DCU
See the Operating Instructions
(202)
-
New safety
message
-
Generated by: DCU
See the Operating Instructions
(203)
-
Long range
interrogation
-
Generated by: DCU
See the Operating Instructions
0204
AIS: offline
AIS offline
AIS OFFLINE
Generated by: AIS Electronics Unit
Cause/Source: No connection between DCU and Elec-
tronics Unit, no valid IEC 61162 data or reset caused by
the watchdog
Reaction: The Electronics Unit continues operation.
Remedy: The cabling must be checked. It might be
possible to eliminate the fault by switching the voltage
supply to the AIS electronics unit off and then on again at
the ship's mains.
Reaction: The message was displayed for a short time
during a reset of the system that was caused by the
internal watchdog. The Electronics Unit continues opera-
tion.
(205)
-
Channel
management
changed
-
Generated by: DCU
See the Operating Instructions
Fault
Messages at
Error Message generated by,
Possible Cause/Source,
Reaction of the System,
Remedy
1000 Series,
CHART-
PILOT, MULTI-
PLOT 910x
(Chart Mode)
DCU
Radar 9xxx,
MULTIPILOT
910x (Radar
Mode)
Summary of Contents for UAIS1900
Page 1: ...SAILOR UAIS1900 Universal AIS Transponder Technical Manual ...
Page 107: ......