background image

 

www.vega-absolute.ru 

 

 

 

 

 

RADIO CHANNEL PACK 

VEGA RK-2.4 

User manual 

 

 

 

 

 

 

 

 

The Vega RK-2.4 pack consists of two RF tags, a wireless locking 
relay, and a reader that can communicate with tags and relays 
over the air.  

The reader can be used both with tags without relays and with 
relays without tags, depending on the specific task. 

 

Summary of Contents for VEGA RK-2.4

Page 1: ... manual The Vega RK 2 4 pack consists of two RF tags a wireless locking relay and a reader that can communicate with tags and relays over the air The reader can be used both with tags without relays and with relays without tags depending on the specific task ...

Page 2: ...4 pack Document type Manual Document code В 01RK2 4 01 Number and data of last revision 01 of 21 08 2017 This document is applicable for following devices Line Device Reader RF tag Wireless locking relay Revision history Rev Date Name Commentary 01 21 08 2017 КЕВ Document creation date ...

Page 3: ...ION diagram 7 Wireless locking relay 8 RF TAGS 8 READER 8 4 OPERATION DESCRIPTION OF THE READER WITH LOCKING RELAY 9 Motion detector in locking relay 9 Oрeration description of the relaY 9 5 RELAY AND TAGS REGISTRATION 11 Alert signals of the reader 11 TAg registration 11 Relay registratiON 12 Nulling of the relaY 13 6 STORAGE AND TRANSPORTATION RULES 14 7 DELIVERY SET 15 8 WARRANTY PACKAGE 16 ...

Page 4: ...ader that works with tags and relays via radio channel produced by Vega Absolute LLC and defines the order of installation and connection and contains a description of the settings and functionality The manual is intended for specialists who are familiar with the rules for performing repair and installation work and who have professional knowledge in the field of electronic and electrical equipmen...

Page 5: ...wo RF tags a wireless locking relay and a reader that can communicate with tags and relays over the air The pack is intended for use in conjunction with a monitoring device that controls the locking relay using the reader as an intermediary Fig 1 1 External view of the RK 2 4 pack from top to bottom blocking relay RF tag reader ...

Page 6: ...rcuit transceiver receiving mA 17 RF TAG Parameter Value Housing dimensions mm 41 х 30 х 5 Ingress protection rating IP54 Battery CR2032 3V 220 mAh Operating temperatures С 40 85 Operating frequency band MHz 2400 2525 Consumption current in sleep mode μA 1 8 2 Minimum battery life years 1 5 READER Parameter Value Housing dimensions mm 45 х 21 х 12 Ingress protection rating IP53 External supply vol...

Page 7: ...ice The locking relay is powered from a 12 V source which may not be associated with the reader s power supply there may be own power supply of any vehicle unit for example the power supply circuit of a gasoline pump The blocking relay is included in the required blocking power circuit The reader works with a relay regardless of tags Therefore if necessary the pack can be organized both for workin...

Page 8: ...hat the relay is controlled entirely by radio there is no need to connect the relay to the general power supply of the standard wiring to which the reader is connected RF TAGS The tag communicates once a second The tag has two operation modes programming and normal Programming mode is used to register tags into the reader The programming mode is turned on for 1 second only when the tag is powered ...

Page 9: ...tile memory and if the previous status from the non volatile memory was active then the motion control starts immediately 5 seconds after the relay is turned on If the previous blocking status from the non volatile memory was inactive then within 15 seconds while the status request is in progress the movement is not controlled the circuit is normally closed If there is no response from the reader ...

Page 10: ...VEGA RK 2 4 User manual 10 Rev 01 of 21 08 2017 try to communicate with the reader for 15 seconds if the reader does not respond it will automatically set the blocking status and start motion control ...

Page 11: ...on was successful then three impulses at the presence output All impulses go with a period of 1 second duty cycle 2 and their number shows the number of tags already written into the reader Up to three marks can be entered into the system memory Three memory cells are used to store codes of three tags The first registerable tag is stored in the 1st cell the second in the 2nd the third in the 3rd B...

Page 12: ...o register each relay separately for making sure that each relay is registered To register switch the reader into the programming mode hold the button for 5 seconds in the same way as for the tags the relay can be registered together with the tags Next apply power to the assigned nulled relay if the relay is registered then 4 impulses will appear at the presence output Then apply power to the next...

Page 13: ...V to the black wire and ground to the red wire The relay will start reset its registration and click the key 3 times Nulled relay can be registered again if the relay is not nulled then it does not make registering requests at startup When connecting the relay it is necessary to observe the polarity red 12V black ground Otherwise the relay will be deleted and you will need to register the relay ...

Page 14: ...ated rooms at a temperature from 5 С to 40 С and a relative humidity of no more than 85 Transportation of kits is allowed in covered cargo compartments of all types at any distance at temperatures from 40 С to 85 С After transporting the devices at negative temperatures it is recommended to keep them at room temperature for 24 hours before using them ...

Page 15: ...s supplied with the following configuration Wireless relay 1 pc Reader 1 pc RF tag 0 2 pcs 1 Battery CR 2032 0 2 pcs 2 Factory certificate 1 pc 1 The number of RF tags may vary in depend on the order conditions 2 The number of batteries corresponds to the number of supplied RF tags ...

Page 16: ...ation storage and operation specified in this user manual The warranty does not apply for batteries devices with mechanical electrical and or other damage and defects arising from violation of the conditions of transportation storage and operation incomplete devices devices with traces of repair outside the manufacturer s service center devices with traces of oxidation or other signs of liquid ent...

Page 17: ...VEGA RK 2 4 User manual 17 Revision 01 of 21 08 2017 vega absolute ru User manual Vega Absolute LLC 2017 2021 ...