SAILOR 100 Satellite TV system
2-8
Chapter 2: Introduction
98-136280-B
ACU interfaces
The ACU has the following interfaces and switch:
• 4 x F-connector for TV outputs (75 Ohm).
• Ground stud
• N-connector for ADU cable (50 Ohm).
• Connector for DC out (for internal use).
• SMA connector for RF RX output (50 Ohm) (for internal use).
• Multi connector for NMEA interfaces (for input from GPS compass or Gyro compass).
• X1 connector (reserved for future use).
• X2 connector (reserved for future use).
• 4 x LAN ports for system operation and maintenance and control interface to Control
Panel and SAILOR Transmodulator, plus 1 x LAN port at the front.
• Power connector.
• On/Off power switch
Service friendly
You can do remote diagnostics and service with the ACU. Its built-in test equipment
checks constantly the ACU’s modules for proper functioning, it monitors and logs for all
modules. It performs POST (Power On Self Test) and you can request a PAST (Person
Activated Self Test). Continuous Monitoring (CM) is also available. BITE error codes can
be read out in the web interface, the Control Panel and in the display of the ACU.
Figure 2-6: SAILOR 100 Satellite TV ACU, connector overview
NMEA
(reserved)
(reserved)
LAN 1
Power On/Off
LAN 2
LAN 3 LAN 4
.
Service port
TV output
Set to On
ADU
V
Cable to front LAN connector
Low
H
Low
V
High
H
High
RX
DC out
Cables to internal connector
Ground
Set to On
SAILOR100IM.book Page 8 Friday, January 18, 2013 10:28 AM
Summary of Contents for 100
Page 1: ...INSTALLATION MANUAL SAILOR 100 Satellite TV ...
Page 2: ......
Page 8: ...vi 98 136280 B SAILOR100IM book Page vi Friday January 18 2013 10 28 AM ...
Page 141: ...Appendices SAILOR100IM book Page 1 Friday January 18 2013 10 28 AM ...
Page 142: ...SAILOR100IM book Page 2 Friday January 18 2013 10 28 AM ...
Page 178: ...Glossary Glossary 4 98 136280 B SAILOR100IM book Page 4 Friday January 18 2013 10 28 AM ...
Page 185: ......