5.3 Ethernet modem statistics
Ethernet modem statistics window shows the full Ethernet and framing statistics of CFIP
modem since unit start or statistics reset. All statistics are also accessible using command
prompt command
ethernet statistics all
.
Explanation of fields:
1. Shows time period during which statistics have been gathered;
2.
Modem state
–
shows if the modem is operating correctly;
3.
Clear statistics
–
resets all statistics counters (not available for “guest”
account);
4.
Truncated frames
– number of truncated received frames;
5.
Long events
– frames having byte count greater than MAXIMUM FRAME
SIZE parameter (1518, 1536 or 1916 bytes);
6.
Vlan tags detected
–
VLAN tagged frames;
7.
Unsup. opcodes
– frames recognized as control frames but contained an
Unknown Opcode;
8.
Pause frames
– frames received are control frames with valid PAUSE
opcodes;
9.
Control frames
– frames received as control frames;
10.
Dribble nibbles
–
indicates that following the end of the packet additional 1 to
7 bits are received. A single nibble, named the dribble nibble, is formed but
not sent to the system;
11.
Broadcasts
– packets, which destination address contained broadcast
address;
12.
Multicasts
– packets, which destination address contains multicast address;
13.
Dones
– reception of packets successfully completed;