The CFIP Lumina Series Full Outdoor Unit Technical Description and Configuration Guide
•
Rev. 1.3
•
© SAF Tehnika JSC 2010
45
1.
FODU name (Max length: 17 characters)
–
allows entering preferable system
name. It is recommended to name the system after its geographic location.
Maximum length of the user name cannot exceed 17 symbols. Default name
is „SAF‟ (command line –
system name
<name>
);
2.
Pressing “Execute configuration” applies changes made to the corresponding
section only for the local side CFIP Lumina
. If “Rollback on” is selected,
configuration will be reverted in case of erroneous configuration changes
applied.
4.2.3 Other configuration
1.
Web refresh (2
..
600 sec)
–
allows specifying time interval of Web data
refreshing. The default value is 5 seconds. You can choose between 2 and
600 seconds (10 minutes) (command line
–
web refresh
<web refresh
time>
);
2.
Time (Usage: YY-MM-DD HH:mm:ss)
–
allows changing system date and
time manually
by entering date and time in specific syntax. “
Set local
machine time
” button forces system to use the time set on your PC or laptop,
from which you are connected to the Web interface (command line
–
system
time
[yyyy-mm-dd hh:mm:ss]
);
3.
Pressing “Execute configuration” applies changes made to the corresponding
section only for the local side CFIP Lumina
. If “Rollback on” is selected,
configuration will be reverted in case of erroneous configuration changes
applied.
4. Writes to configuration file all the changes made on the whole page
(command line
–
cfg write
);
5. Restarts CFIP Lumina you are connected to.
(command line
–
system reset
);
(!)
Note that after restarting the CFIP will use only those settings, which are
written to the configuration script. Other settings will be set to default values
.