FUEL, FUELING INSTRUCTION
Operation
Aircraft Operations Manual
9/2.2
PAGE
8
Jun 01/17
CONDITIONS
NORMAL PROCEDURES
(Cont’d)
8. DE
−
FUEL switch
. . . . . . . . . . . . . . . . . . . . . . . . . . .
In cockpit
9. L/R STBY PUMP switch
AUTO
. . . . . . . . . . . . . . . . . . . . .
10. XFEED switch
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
−
Check XFEED ON light to go out, indicating
crossfeed valve is fully closed.
11. Continue with item 16 below.
9.
XFEED switch
ON
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
−
If defueling only bright tank, leave switch in OFF.
−
Check XFEED ON light to come on.
10.
CONN VALVE switch
CHECK CLOSED
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Outside the aircraft
11.
Order suction defuel to start.
12.
Monitor defueling on the fueling panel.
When correct fuel quantity is reached
13.
Order suction defuel to stop.
14.
DE
−
FUEL switch
CLOSE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
In cockpit
15.
XFEED switch
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Outside the aircraft
16.
FUEL PANEL switch
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
17.
Disconnect fuel nozzle.
−
Check receptacle for leaks.
−
Install cap on receptacle.
18.
Fuel panel access door
CLOSE
. . . . . . . . . . . . . . . . . . . . . . . . . .
19.
Ground connection bonding cable
REMOVE
. . . . . . . . . . . . . . . . .