FUEL, FUELING INSTRUCTION
Operation
Aircraft Operations Manual
9/2.2
PAGE
4
Jun 01/17
CONDITIONS
NORMAL PROCEDURES
(Cont’d)
In cockpit
2.
Overhead fuel panel
CHECK
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
−
Switches to be in normal position, i.e. AUTO/CLOSED/OFF.
3.
Condition levers
CHECK FUEL OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Outside aircraft
4.
Overboard vents
CHECK
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
−
Check to be free of obstructions.
5.
Clearance aircraft/ground equipment
CHECK
. . . . . . . . . . . . . .
−
The increasing fuel load will compress the landing gear shock struts.
6.
Ground connection bonding cable
CONNECT
. . . . . . . . . . . . . . . . .
−
Bonding cable from fuel truck connected to the grounding point beside the
fueling panel.
7.
Fueling access door
OPEN
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
−
Check all switches to be OFF/CLOSE.
−
Remove cap on receptacle.
−
Connect fuel nozzle.
8.
FUEL PANEL switch
FUEL PANEL
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
9.
IND TEST button
DEPRESS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
−
Check quantity indicators to show:
without mod. 2091:
950
"
50 lb (432
"
23 kg)
with mod. 2091:
1000
"
50 lb (455
"
23 kg).
10.
OVERFULL lights
DEPRESS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
−
Check light function.
11.
Fueling control switches
SET
. . . . . . . . . . . . . . . . . . . . . . . . .
−
Select MID LEVEL or FULL LEVEL as required. The fueling will stop auto-
matically when selected level is reached.
−
If an intermediate level is required, select FULL LEVEL and then switches
to OFF when the required quantity is reached.