FIRE PROTECTION
Description
Aircraft Operations Manual
7.1
PAGE
3
Apr 01/15
2.5
Optional cargo compartment fire extin-
guisher system
An optional extinguisher system, identical to the
standard system, may be installed on the left side
of the cargo compartment.
Like the standard system, the extinguisher is dis-
charged in two stages, the first with rapid flooding
and the second with a slower regulated flow. The
time difference between activation of FIRE EXTG 1
and 2 must therefore be more than 2 minutes to
prevent a pressure chock due to two successive
flooding discharges.