FUEL, FUELING INSTRUCTION
Operation
Aircraft Operations Manual
9/2.2
PAGE
7
Jun 01/17
CONDITIONS
NORMAL PROCEDURES
(Cont’d)
2.
Clearance aircraft/ground equipment
CHECK
. . . . . . . . . . . . . .
−
The change in fuel load may change the landing gear shock strut exten-
sion.
3.
Ground connection bonding cable
CONNECT
. . . . . . . . . . . . . . . . .
−
Bonding cable from fuel truck connected to the grounding point beside the
fueling panel.
4.
Fueling access door
OPEN
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
−
Check all switches to be OFF/CLOSE.
−
Remove cap on receptacle.
−
Connect fuel nozzle.
5.
FUEL PANEL switch
FUEL PANEL
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.
IND TEST button
DEPRESS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
−
Check quantity indicators to show:
without mod. 2091:
950
"
50 lb (432
"
23 kg)
with mod. 2091:
1000
"
50 lb (455
"
23 kg).
7.
DE
−
FUEL switch
DE
−
FUEL
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
In cockpit
8.
Condition levers
CHECK FUEL OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pressure defueling
2. XFEED switch
ON
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
−
Check XFEED ON light to come on.
3. CONN VALVE switch
CHECK CLOSED
. . . . . . . . . . . . . . . . . . . . . . . .
4. L/R STBY PUMP switch
OVRD
. . . . . . . . . . . . . . . . . . . . .
−
For both tanks set both switches to OVRD.
−
For one tank set associated switch to OVRD.
Outside the aircraft
5. Order defuel to start.
6. Monitor defueling on the fueling panel.
When correct fuel quantity is reached
7. Order defuel to stop.
(Cont’d)