FUEL
Description
Aircraft Operations Manual
9/1.1
PAGE
11
Apr 01/15
A11396
A
FUEL CONTROL PANEL
A
XFEED ON light (amber).
Comes on when the crossfeed is open.
L/R FUEL FILTER light (amber).
Comes on if the fuel filter becomes clogged and
the fuel is bypassing the filter.
XFEED valve switch.
When set to ON the crossfeed valve will open
and the XFEED ON light will come on indicating
valve is open.
L/R LOW LEVEL light (amber).
Comes on if the fuel quantity in corresponding
tank is below 300 70lb or 135 30kg.
CONN VALVE OPEN light (amber).
Comes on when the interconnect valve is open.
CONN VALVE switch.
When set to OPEN the interconnect valve will
open and the CONN VLV OPEN light will come
on, indicating valve is open.
L/R STBY PUMP switch.
OFF
−
Pump is off.
AUTO
−
Pump starts automatically if corre-
sponding main pump pressure is low
and condition lever out of FUEL OFF
position.
OVRD
−
Override, pump is on.
L/R STBY PRESS light (green).
Comes on if a standby pump pressurizes the
engine feed line, direct or through crossfeed.
L/R MAIN PUMP light (amber).
Comes on if main pump pressure is low.
L/R VALVE CLOSED light (amber).
Comes on when the fire shutoff valve is closed.
Fig. 7 Fuel system
−
fuel control panel