DT Etherlink IV
User Manual
- 56 -
4.6.4.3 <STATUS> Command
The <STATUS> command displays the actual status of the SHDSL transceiver.
CO_FMM>STATUS
----------------------------------------------------------------------------
Status : DSL1 DSL2
----------------------------------------------------------------------------
I/F mode : CO CO
SYNC : - -
SEGD : - -
Power backoff : 0.0 0.0 dbm
Far end power backoff : 0.0 0.0 dbm
Loop attenuation : 0.0 0.0 dB
NMR : 0.0 0.0 dB
Bitrate : 0 0 kbit/s
SRU # : 0 0
Active sync. source : Internal Internal
----------------------------------------------------------------------------
Temperature : 39.750 C
----------------------------------------------------------------------------
CO_FMM>
Option: T
– update the table continuously.
Option: L
– show the DSL and Link parameters. For the STATUS L explanation please see the
CONFIG command explanations.
Table 4.2 <STATUS> definitions
Parameter
Value
Description
I/F mode
CO
CP
The interface is in the Master mode
The interface is in the Slave mode
SYNC
1
- (0)
Synchronization in the SHDSL line is established
Synchronization in the SHDSL line is absent
SEGD
1
0
-
Transmitted data over the SHDSL line are valid
Transmitted data over the SHDSL line are not valid
Data are not received
Power backoff
N
Output signal power [dBm]
Far end power backoff
N
Output signal power [dBm] remote side
Loop attenuation
N
Attenuation in the loop [dB]
NMR
N
Maximum possible increase in the noise margin for which the
BER is expected to be not less than 10
-7
[dB]
Bitrate
N
Data transmission rate of the SHDSL line [kbit/s]
SRU #
N
Number of regenerators in the system
Active sync. source
External
E1-1
E1-2
E1-3
E1-4
Internal
External sync
Е1-1 network interface
Е1-2 network interface
Е1-3 network interface
Е1-4 network interface
Internal sync source
Temperature
N
Unit temperature [С
]