DT Etherlink IV
User Manual
- 48 -
4.6.2 General Commands
4.6.2.1 <H> Command
After the <H> command is entered the device displays the help menu.
4.6.2.2 <APPLY [ALL/GROUP]> Command
This command is used to apply changes in all groups or to apply changes in one of these groups:
LINE, VLAN, NET, and SNMP. As a result, changes in the group are written from the new
configuration into the running one. Examples:
CO_FMM>APPLY
Applying all configuration changes to running configuration
CO_PM>APPLY LINE
Applying configuration changes in group LINE to running configuration
4.6.2.3 <CONNECT N:1..13/R> Command
The <CONNECT N:1..13/R> commands initialize the management of the remote device. The
parameter N sets the number of the SHDSL channel, over which the connection is initialized. In
single-channel systems the parameter N can be absent.
Notes:
1. The <CONNECT R> command in the Slave mode is only available if the Master
device can be configured locally at this instant.
2. The <CONNECT N> (N=1..13) command initializes the management of the remote
regenerator. The <CONNECT N> command is only available in the Master mode.
3. This command is not provisioned for regenerators.
4. If the channel of remote management is blocked (for example, a message or a
table are not displayed completely), press Enter.
4.6.2.4 <LINK [SN/00/FE]> Command
The < LINK [SN/00/FE]> command establishes connection to specified unit over the backplane.
SN - Specifies the slot number of a subrack unit to connect with. If the backplane is busy or if the
specified subrack slot is free (or no response in 1.5 first seconds) the "LINK ERROR" message
will be issued by the unit. For subrack units SN should not be 00.
00 - (double zero) Switches on the Monitor (Local Craft Terminal) connector control mode for
Minirack and standalone units. In this mode all typed characters will be translated to the Monitor
connector.
FE - (for ever) Switches on Monitor connector control mode for common CLI RS232 units. In this
mode all typed characters will be translated to Monitor connector. The connection will be
established until a terminal timeout appears.
Example:
LINK 10 - Establish connection to subrack unit with slot number 10.
LINK 00 - Establish monitor control node.
LINK FE - Establish monitor control node.
Notes:
To refuse link connection just exit from controllable unit.
To refuse link connection urgently use CTRL+Z keystroke.
4.6.2.5 <LINKCLEAR> Command
The < LINKCLEAR > command closes current virtual link connections.