Installation, operating and maintenance manual SKIT/S-DEB
3rd print version
page 53
10 – Operation
RWO GmbH
●
Marine Water Technology
●
Bremen
●
Germany
Issue 2014-04-10
10.4
Meaning of the message lights
Designation Colour Condition
Meaning /
cause
POWER
White Main Switch "On"
power supply
is provided,
voltage is
applied
FAILURE
Red
One or more alarm
states pending
The alarm
trigger is
shown as a
text message
on the display
BILGE
LEVEL
Green Floating switches
in the bilge or the
bilge water tank
indicate
"Wastewater
present"
Display of
wastewater
level! If no
floating
switches must
be connected,
you must
bridge the
corresponding
terminals, else
automatic
operation in
the oil
separator
cannot start.
STATUS
Green
Water-
Discharge
Red
Oil-
Discharge
Orange-
Flushing
Green System in
operation
The display shows
" ENTOELEN"
Cleaned water
is delivered
Red
System in
operation
The display shows
"DISCHARGE"
Oil or air is
discharged to
the oil
collector tank
Pump and
electric heater
are switched
off
Valve 4 and
15 are open
Orange
System in
operation
The display shows
"FLUSHING"
The backflush
process is
running
Pump and
electric heater
are switched
off
Valve 5 and
15 are open
Tab. 14 Meaning of the message lights