Installation, operating and maintenance manual SKIT/S-DEB
3rd print version
page 58
10 – Operation
RWO GmbH
●
Marine Water Technology
●
Bremen
●
Germany
Issue 2014-04-10
For better overview, the 16 data are separated by points
into blocks of 4. 14 of the 16 data derive from input 1 to
14. The last two input data derive from the sensor
electrodes. If the measured resistance exceeds the
threshold for oil detection, the input is displayed as "1". If
the resistance falls below the threshold for water
detection, the input is displayed as "0".
Note
The threshold value of the sensor electrodes is set
by factory default to usual bilge waters and oils and
generally does not need to be adjusted. If in special
cases an adjustment to special conditions on board
is necessary, contact RWO service by all means
(
à
1.5 Contact information).
Notes on output mapping
10.5.6
AUSGANG:
1000.0111.00
OUT:
1000.0111.00
The output image displays the state of the 10 output
relays. "0" indicates that the relay is switched off. "1"
means that the relay is switched off. For better overview,
the 10 states are divided by points into blocks of 4.
Branching to the user settings
10.5.7
In the submenu user settings you can view and modify
these settings. For this purpose you must set a branch to
this level. To do so, activate the field "Yes" at the main
item using the + button.
Display of the main menu item after pressing the +
button ("Yes" flashes)
KUNDENPARAMETER
AENDERN? NEIN JA
USER SETTINGS
MODIFY? NO YES
After pressing the Enter button:
Query of the customer passwort (PIN = 7963)
KUNDENPASSWORT:
0000
USER PASSWORD
0000
First the first digit of the password is activated (flashes).
Use the +/-buttons to set the digit. If the digit is set as
desired, activate the next digit with the Enter button.
Pressing the Enter button after setting the forth digit will
check the password. If the password is incorrect, the
following message appears:
PASSWORT FALSCH!
BITTE NEU EINGEBEN!
WRONG PASSWORD!
PLEASE RETYPE
PASSWD