NOTICE:
THE CYCLONIC SEPARATOR AND FILTER CANISTER WILL
NOT DRAIN IF THE VACUUM SYSTEM IS OPERATING.
A LWAY S M A K E S U R E T H E S Y S T E M I S C O M P L E T E LY
SHUTDOWN BY REDUCING ENGINE SPEED TO IDLE AND
DISENGAGING THE BLOWER BEFORE DRAINING THE
SEPARATOR BOX OR FILTER CANISTER.
The vacuum filter is a pleated, reusable filter that
is easily accessed through the door on the side
of the canister. Once the filter has been removed
you should de-grease with detergent and power
wash at 2000 psi (138 BAR). A mild solvent solu-
tion may be used to clean thermoplastic or tar
residue from the filter surface. Always check to
ensure there are no damaged areas or holes that
could allow debris to get into the vacuum blower
or silencer. Replace the filter if it is damaged or
shows any sign of deterioration.
Blower internal components must be protected
from corrosion with light oil such as WD-40, LPS or
CRC when the system is shutdown for the evening
or an extended period. This is accomplished by
opening the access door and removing the plug
in the filter element while the blower is operating.
Allow the blower to operate for several minutes to
dry out blower components, then reduce engine
speed to idle and spray oil into the port for 20-
30 seconds. Reinsert the plug when done. Refer
to the Operation and Lubrication & Maintenance
sections for additional information on maintaining
and protecting the blower.
Vacuum Filter Canister,Door,Filter Element & Plug
Summary of Contents for RH7500
Page 1: ...RH7500 Operations Manual ...
Page 2: ......
Page 6: ...6 NOTES ...
Page 10: ...10 NOTES ...
Page 19: ...19 Section 1 Safety Information ...
Page 20: ...20 NOTES ...
Page 108: ...108 NOTES ...
Page 150: ...150 NOTES ...
Page 155: ...155 Appendix 3 Tools Spare Parts ...
Page 156: ...156 Appendix 3 Tools Spare Parts ...
Page 158: ...158 NOTES ...
Page 163: ......