145
Section 4 - lubrication & maintenance
Typical Vacuum Blower Gear Case Drain, Oil Level & Oil Fill Plugs
A. Drain Valve & Safety Plug B. Overflow Plug C. Breather/Oil Fill Plug
A
B
C
4.16 checking & changing
Blower Gear case oil
The blower gear case oil level should be checked
daily or at least every 50 hours of operation. The
oil should be changed every 500 hours.
When changing or checking the gear case oil,
always clean the area around the breather and
overflow plugs before they are removed. This will
reduce the possibility of dirt and debris from enter-
ing the gear case when the fill plugs are removed.
Checking The Gear Case Oil Level
1. Make sure the system is shutdown with the
truck in the service position and on level
ground.
2.
Remove the overflow plug on the side of the
gear case. The oil should be within 1/4” of the
bottom of the plug threads.
3. If the oil is low, remove the breather plug and
add oil until the oil level is even with the bot-
tom of the overflow hole.
4. Replace the breather and overflow plugs.
Tighten to specifications.
Changing the Gear Case Oil
Draining the gear case:
1. Make sure the system is shutdown with the
truck in the service position and on level
ground.
2. Remove the safety drain plug at the oil drain
ball valve fitting.
Summary of Contents for RH7500
Page 1: ...RH7500 Operations Manual ...
Page 2: ......
Page 6: ...6 NOTES ...
Page 10: ...10 NOTES ...
Page 19: ...19 Section 1 Safety Information ...
Page 20: ...20 NOTES ...
Page 108: ...108 NOTES ...
Page 150: ...150 NOTES ...
Page 155: ...155 Appendix 3 Tools Spare Parts ...
Page 156: ...156 Appendix 3 Tools Spare Parts ...
Page 158: ...158 NOTES ...
Page 163: ......