RDC6445GT5 Laser cutting system hardware user manualV1.1
深圳市睿达科技有限公司
67
10.2 Alarm information
The system will detect faults in real time and prompt the corresponding information or alarms to avoid
unnecessary losses. The alarm information is described as below:
Alarm type
Reasons
Solutions
Water protection failure Water cooling system failure,
incorrect sensor wiring
Check the water-cooling system and
refer to the relevant wiring description
in the user manual for correct wiring
Temperature, sensor abnormal
Lower the water temperature and check
if the sensor returns an effective signal
Cover protection
Sensor wiring incorrect
Refer to the relevant wiring description
in the user manual for correct wiring
Sensor abnormal
Check if the sensor returns an effective
signal
Over breadth
Graphics processing position over
the breadth
Re-check if the processing positioning
position is reasonable
X/Y/Z/U
axis
Over
breadth
Graphics processing position over
the breadth
Re-check if the processing positioning
position is reasonable
Insufficient
motion
buffer distance
Caused by too fast graphics
processing speed
Increase
acceleration
or
arrange
graphics to the center for processing