RDC6445GT5 Laser cutting system hardware user manualV1.1
深圳市睿达科技有限公司
60
during operation, the maximum power set by the user can’t be higher than the maximum power value
set here, and the minimum power value set by the user cannot be lower than the minimum power value
set here; if the power has attenuated after using the laser source a period of time, the laser power can
be fine-tuning by setting the laser source attenuation coefficient. The attenuation coefficient is 0 when it
is not attenuated.
If only a single channel laser tube is configured, only one channel of laser
parameters will be displayed.
(
3
)
Other vendor parameters
Machine configuration
Transmission mode: generally, the “Belt Stepping Type” should be selected. When
other types are selected, the control algorithm will change slightly.
Feeding mode: one-way / two-way optional. When it is a one-way feed, it can always
feed in one direction without checking the coordinates; when a two-way feed is selected, the
system will check the maximum and minimum coordinates. Feed materials in one direction at
odd times, and feed materials in the other direction at even times. The initial direction of the
first time can be changed by setting the direction polarity or modifying the positive and
negative values of the feed length. This parameter is valid only when the “Z Axis Function” is
configured as “Feeding Axis”.
Power outage delay: 0~3000ms can be set.When the power grid is cut off, the system
power supply will not drop to 0V immediately. There is a delay during this period, the delay
value set here should be basically consistent with the actual power outage delay value. If the
setting value deviation is relatively large, when the power is cut and engraving is continued,
the graphics processed for the second time and the graphics before the power outage are
either unclosed or overlapped too much.
Quantity of laser heads: select the quantity of the working laser head.
Double heads spacing:
when double laser heads, the safe distance between the two.
Cover opening protection:
when this item is enabled, the controller must be
connected to the cover opening protection circuit, otherwise the machine will not work.
Fan enable: if you want to use the Wind signal of output port to control the switch of
the fan in layers, you must enable this parameter, otherwise the Wind signal outputs other
signals.
Water cooling alarm: when the water protection is enabled, the controller must be
connected to the water protection circuit, otherwise the machine will not emit light. If the
water protection is not enabled, the water protection circuit can be disconnected and the
controller will not detect it.
Adsorption on delay: delay time before adsorption on.
Adsorption off delay: delay time after adsorption off.
Power off delay: 0~300.
Prompt