The maximum velocity that the machine allowed.
Start velocity
The start frequency of the motors.
Maximum accelerator
The maximum accelerator that the machine allowed.
Emergency stop accelerator
When the axis made the limit or the alarm valid, system will emergent stop with this
accelerator.
Manual accelerator
If you use the manual operation panel, axis moves with the accelerator
If all the parameters is configured, you can click the “write” to download the parameters to the memory of
controller for a
permanent saving. You can still upload the parameters form the controller
’s memory. You can
still upload the parameters from a file named *.rdset.
2 Cut parameters
Cut parameters are include of motion parameters and delay parameters. As is shown in picture 3-20.
Picture3-20 Cut parameter set up
(
1
)
Cut parameter
Jump velocity
、
Jump accelerator
The velocity and accelerator of the jump motion. There is no laser emit during the jump
movement. So the velocity is usually to be set much larger than the cut velocity and
accelerator.
Look ahead coefficient.
The look ahead coefficient will affect the turning corner velocity. If there is a serious shake
during turning corner, the ahead coefficient should be decreased.
Cut accelerator