RUGGEDCOM RSG2488
User Guide
Chapter 4
System Administration
Authentication Related Security Alarms
101
Parameter
Description
Name
Synopsis:
Any 34 characters
Default:
sys_alarm
The alarm name, as obtained through the
alarms
CLI command.
Level
Synopsis:
{ EMRG, ALRT, CRIT, ERRO, WARN, NOTE, INFO, DEBG }
Severity level of the alarm:
• EMERG - The device has had a serious failure that caused a system reboot.
• ALERT - The device has had a serious failure that did not cause a system reboot.
• CRITICAL - The device has a serious unrecoverable problem.
• ERROR - The device has a recoverable problem that does not seriously affect
operation.
• WARNING - Possibly serious problem affecting overall system operation.
• NOTIFY - Condition detected that is not expected or not allowed.
• INFO - Event which is a part of normal operation, e.g. cold start, user login etc.
• DEBUG - Intended for factory troubleshooting only.
This parameter is not configurable.
Latch
Synopsis:
{ On, Off }
Default:
Off
Enables latching occurrence of this alarm in the Alarms Table.
Trap
Synopsis:
{ On, Off }
Default:
Off
Enables sending an SNMP trap for this alarm.
Log
Synopsis:
{ On, Off }
Default:
Off
Enables logging the occurrence of this alarm in syslog.txt.
LED & Relay
Synopsis:
{ On, Off }
Default:
Off
Enables LED and fail-safe relay control for this alarm. If latching is not enabled, this field
will remain disabled.
Refresh Time
Synopsis:
0 s to 60 s
Default:
60 s
Refreshing time for this alarm.
4. Click
Apply
.
Section 4.4.4
Authentication Related Security Alarms
The following describes the authentication-related security messages that can be generated by ROS:
•