Roto E-Tec DoorDrive
IMO_294_EN_v0
May 2013
35
Optional settings
Acoustic signal transmitter, hold-open period
6. Acoustic signal transmitter
This option can be used to set whether you hear a signal or not when you
issue the door with a command or not. The “Successful close signal”
option enables you to choose whether an acoustic signal should be issued
when the door latches shut or not. This is only possible for a lock equipped
with feedback.
NOTE!
In the event of a fault, feedback is always issued in the form
of an acoustic signal.
In the “For start of actuation” setting, you will hear an acoustic signal once
at the start of the process. If you choose “as long as the actuation”, this
signal is repeated until the process is completed. In other words, until the
door is fully opened or closed.
You can also select this setting separately for the opening and closing
process.
DIP switch
Description
Feedback signal
Personal setting
1 0 0 0
0 0
0 0 Feedback on current status
–
0 1 Signal for successful closing* OFF
1
1 0 Signal for successful closing* ON
2
0 1
0 0 Feedback on current status
–
0 1
Signal when opening: None
1
1 0 Signal when opening: During start of actua-
tion
2
1 1 Signal when opening: As long as actuation
issued
3
1 0
0 0 Feedback on current status
–
0 1 Signal when closing: None
1
1 0
Signal when closing:
During start of actuation
2
1 1 Signal when closing: During start of actuation 3
* only effective for lock with feedback
7. Hold-open period
This setting can be used to define the period until the door is automatically
closed. This is only valid however, when the door is electrically opened to
its end position. The time in the table below indicates the timespan in
which the door remains open until an automatic closing process is initiated.
DIP switch
Description
Feedback signal
Personal setting
0 1 1 1
0 0
0 0 Feedback on current setting
(as per operation mechanism)
–
0 1
Automatic closing inactive = Continuous-
ly open
1
1 0 After 5 seconds
2
1 1 After 10 seconds
3
0 1
0 0 After 20 seconds
4
0 1 After 30 seconds
5
1 0 After 40 seconds
6
1 1 After 1 minute
7
1 0
0 0 After 1 minute 15 seconds
8
0 1 After 1 minute 30 seconds
9
1 0 After 1 minute 45 seconds
10
1 1 After 2 minutes
11
1 1
0 0 After 2 minutes 30 seconds
12
0 1 After 3 minutes
13
1 0 After 4 minutes
14
1 1 After 5 minutes
15