Initial operation
Initial operation
2.
Connecting multi-point locking system
Connect Eneo C / CC multi-point locking system with the operation
mechanism as per the wiring diagram to the power supply units.
Switch on power supply units or plug connector into power socket.
ON
1
2
3
4
5
6
7
8
3.
Converting to Roto setting
Activate Roto settings. To do so, switch on power for control system and
set DIP switches to 1111.1010. Confirm by pressing one of the operation
mechanisms for 3 seconds.
NOTE!
Operation mechanisms are Eneo hand-held transmitters
(they have to be programmed beforehand, refer to Eneo C / CC
IMO_190 installation instructions or refer to page 26).
ON
1
2
3
4
5
6
7
8
4.
Teaching-in closed position
Set DIP switches to 1111.0001. Close door and use hand to keep it
closed. Press an operation mechanism for 5 seconds until acoustic
feedback is issued indicating the action was successful.
NOTE!
Use hand to keep door closed until the acoustic feedback is
heard.
ON
1
2
3
4
5
6
7
8
5.
Teaching-in open position
Manually open the door to gain access to the DIP switches.
Set the DIP switches to 1111.0010, move door to the required open
position and hold it there.
Press an operation mechanism for 3 seconds until acoustic feedback is
issued indicating the action was successful.
ON
1
2
3
4
5
6
7
8
NOTE!
A fault reason can also be an error in step 4.
Set the DIP switches to position 0000.0000.
6.
Conducting optional function test
Check closing and opening of the door to match the selected settings or
configurations. The operation mechanism should be able to initiate the
door opening and door closing process.
8.
Setting up delivery status
Set up required delivery status. For example:
Disconnect the power supply unit from the mains, detach connection
to the door
Insert rubber plug into cover opening
Stow away the remote controls and supply unit