24
May 2013
IMO_294_EN_v0
Roto E-Tec DoorDrive
Subject to change.
15.
Connect the second plug-and-socket connector X2
to cable type S as per Table 2 (similar to first plug-
and-socket connector).
Table 2: Assignment of plug-and-socket connector X2
to house wiring / lock to cable type SD
Contact Description
Abbreviation
Wire colour
1
Lock signal
SSIG
2
Lock ground
SGND
3
Lock supply
S+
4
Lock feedback
SRM
5
Driver output
OFF
6
Antenna
ANT
7
Signal 1
IN1
Pink
8
Signal 1 AC
IN1AC
9
Signal 2 /
IN2
Blue
10
Signal 3
IN3
11
Supply voltage
12V
Red
12
Ground
GND
Black
Connect cable – using screwdriver (2.5 x 0.4 mm).
To jam the plug-and-socket connector in place, insert a
screwdriver at an incline onto the outer visible spring in
the terminal strip. The screwdriver opens the spring
contact and sticks there in place (it can then be
released).
Insert the wire and remove the screwdriver again. The
contact numbering is printed on to the side.
The two connectors are coded and they cannot be
interchanged. Therefore, when connecting the lines
make sure that the correct plug-and-socket connector
has been selected.