79-00-00
page 28
May 01/2007
Effectivity 912/914 Series
Edition 1 / Rev. 0
d02628
BRP-Rotax
Maintenance Manual
Fig. 79-21
200
(
Ω
)
(bar)
150
100
50
0
10
8
6
4
2
00229
For sensor resistance see following graph showing sensor resistance
over pressure. Compare pressure gauge with a calibrated instrument.
■
CAUTION: The graph resistance over pressure has been deter-
mined, and is effective at the following conditions only.
ambient temperature:
20 °C (68 °F)
voltage:
12 V
deviation:
max ± 5%
After removal of oil pressure sensor, clean the thread. Apply LOCTITE
243 to thread of sensor and tighten to 15 Nm (133 in.lb).
Fit sensor. See 79-00-00 sec. 3.1.5..