Effectivity 912/914 Series
Edition 1 / Rev. 0
71-00-00
page 17
May 01/2007
d02621
BRP-Rotax
Maintenance Manual
5) Preservation and returning to service
5.1) Storage and preservation directives for a new engine
BRP-Rotax as the manufacturer of the engine warrants corrosion protection of
aircraft engines of the 912 /914 Series for at least 12 months from date of
delivery by BRP-Rotax.
This warranty confirmation is subject to the following conditions:
- The engine must be stored in the original packing as supplied by BRP-Rotax.
- The protective covers must not be removed.
- The engine must be stored in a suitable place (closed area, clean and dry).
If the engine is stored longer than 12 months, the following inspections must be
carried out every 3 months:
- Remove one spark plug on each cylinder and turn crankshaft by hand 2 full
turns. Refit spark plug.
- Visual inspection for rust formation (e.g. on propeller shaft). If rust formation
is detected, the engine must be sent immediately to an authorized overhaul
facility for inspection.
▲
WARNING: The engine must not be taken into operation.
◆
NOTE:
The maximum possible storage period of the engine is limited to
24 months.
If this period is exceeded, the engine must be sent to an ROTAX authorized
overhaul facility for inspection.
Summary of Contents for MMH-912 Series
Page 463: ......