76-00-00
page 22
May 01/2007
Effectivity 914 Series
Edition 1 / Rev. 0
d02626
BRP-Rotax
Maintenance Manual
◆
NOTE:
Because of the multitude of displays, param-
eters important for the user are printed in bold
type and underlined.
MONITOR:
Serves for the on-line display of operational
engine data such as airbox pressure, ambient
pressure, servo position, airbox temperature
etc.
LOG:
Is a submenu (18) of the MONITOR program
and facilitates recording of current operational
data on the hard disk of the connected PC.
Logging is activated and stopped by pressing
the key
L
. The logging status is indicated by
“ON” for on-line recording and “OFF” respec-
tively for non-recording (see Fig. 76-14, item
(5)).
A so-called Log file will be loaded onto the
hard
disk
stating date and starting time of the
recording.
Example:
◆
NOTE:
Verify this date and starting time when booting
the PC.
If more than 4000 data lines are recorded, the
current LOG file will be closed automatically
and a new one opened.
00193
Fig. 76-15
11061014.LOG
Minute (minute)
Stunde (hour)
Tag (day)
Monat (month)
Summary of Contents for MMH-912 Series