![Rotax 912 ULS 3 Installation Manual Download Page 95](http://html1.mh-extra.com/html/rotax/912-uls-3/912-uls-3_installation-manual_1489784095.webp)
Effectivity: 912 Series
Edition 1 / Rev. 0
d04057
page 95
May 01/2007
BRP-Rotax
INSTALLATION MANUAL
-
connection for starting carb (choke) actuation (3)
connection on choke lever:
clamping nipple 6
(suitable for 1,5 mm (.06 in.) steel wire)
action travel:
23 mm (
15
/
16
")
actuating force:
min.10 N (2,2 lb)
max. 45 N (10 lb)
limit load:
100 N (22 lb)
Directive for choke actuation
The choke shaft (3) is marked (4). This mark has to point towards cable
engagement (5).
Fig. 61
00541
5,2
2,2
ø6,7
3
4
5