![Rotax 912 ULS 3 Installation Manual Download Page 58](http://html1.mh-extra.com/html/rotax/912-uls-3/912-uls-3_installation-manual_1489784058.webp)
page 58
May 01/2007
Effectivity: 912 Series
Edition 1 / Rev. 0
d04054
INSTALLATION MANUAL
BRP-Rotax
12.8) Feasible location of radiator
See Fig. 29.
The expansion tank (1) must always be positioned at the highest point of the
cooling system.
■
CAUTION:
If necessary, the radiator outlet opening (8)
may be max.
1,5 m
(5 ft) above or below water inlet bend (5)
on water pump (see Fig.
29).
◆
NOTE:
On the standard engine version the expansion tank (1) is fitted
on top of the engine (see Fig. 29).
max.
250mm /
max.
9.84 in.
max. 1,5 m / max.
5
9.
05 in.
Fig. 29
08319
1
6
8
2
4
5
7
3
For proper operation of the cooling system the expansion tank (1) with pressure
cap (2)
has to remain for all possible engine positions on the highest point of the
cooling circuit.
▲
WARNING: The radiator has to be planned and installed such that the
specified operating temperatures are maintained and the max.
values are not exceeded.
This state has to be warranted for
"hot day conditions"
too!
If need be, take appropriate measures like changing size of
cooler, partial covering of cooler etc.
Additionally the system needs an overflow bottle (7) where surplus coolant is
collected and returned back into the circuit at the cooling down period.