page 94
May 01/2007
Effectivity: 912 Series
Edition 1 / Rev. 0
d04057
INSTALLATION MANUAL
BRP-Rotax
15.2) Connections for Bowden-cable actuation and limit load.
See Fig. 2, 3, 4, 60 and 61.
-
centre position of carburetor socket (P1) of the respective carburetor:
◆
NOTE:
All dimensions to point of reference (P)
-
limit load on point of reference P2
■
CAUTION:
The specified limit loads must never be exceeded.
-
connection (1) for air filter or intake silencer
outside dia.:
50 mm (2 in.)
slip-on length:
12 mm (.47 in.)
-
connection for throttle actuation (2)
connection on throttle lever:
set screw M 5x12
tightening torque: 4 Nm (35 in.lb)
(suitable for 1,5 mm (.06 in.) steel wire)
action travel:
65 mm (2
1
/
2
")
actuating force:
min. 1,5 N (.3 lb)
max. 8 N (1,8 lb)
limit load:
20 N (4,5 lb)
◆
NOTE:
Throttle opens by spring.
P2
106
P1
P1
P1
P2
P1
Fig. 60
00538
1
3
2
carburetor for
x Achse y Achse
z Achse
cylinder 1/3
-521
-180
25
cylinder 2/4
-553
180
25
coordinates P1 [mm]
09190
reference point P2
max. allowable forces
(limit load) in (N)
in x,y and z axis
60
max. allowable bending moments
(limit load) in (Nm)
in x,y and z axis
4
02028