12.11.1)General directives for ducting of the cooling air
See Fig. 2/3/4.
For front installation in a closed fuselage, ducting of cooling air to the
cylinders is recommended. In this case a costly horizontal partitioning
(baffles) can be avoided.
◆
NOTE:
The engine remains in this case completely on the
warm side of the engine compartment and is very well
accessible. In special cases a separate cold air supply
to the air intake filters has to be provided.
BRP-Powertrain has developed especially for this application a non-
certified cooling air ducting.
▲
WARNING:
Certification to the latest requirements to FAR or
EASA has to be conducted by the aircraft manufac-
turer.
The following recommendations should assist the aircraft manu-
facturer at the planning of a suitable cooling air ducting.
-
The cooling air ducting to be adequate to transfer thermal energy
of approx. 6 kW (5,7 BTU/s) at take-off power.
-
required cross section of air duct: at least 100 cm
2
(16 in
2
)
-
material:
glass fibre reinforced plastic or heat resistant non-inflammable
material.
-
attachment:
formlocking on engine case and cylinders
◆
NOTE:
In case formlocking attachment won`t be adequate,
additional attachment is possible on two tapped lugs
M8 on top side of engine.