Ross nielsen NWE-IP User Manual Download Page 37

NWE-IP User Guide (v5.0)

Configuring the Timing Settings • 37

Configuring the Timing Settings

The NWE-IP supports the Precision Time Protocol (PTP) as defined in the IEEE 1588-2008 standard and the 

SMPTE ST 2059 specification.

Configuring the PTP Settings

From the Timing tab in DashBoard, you can synchronize the NWE-IP to real-time clocks of other devices in the 

same network.

There are several criteria that PTP clocks compare to determine who will be master and who will be slave (called 

the Best Master Clock Algorithm, or BMCA), and they are evaluated in order: Priority1, clock class, accuracy, 

scaled log variance, Priority2, clock ID (similar to the MAC address). Practically, Priority1 is the only setting 

configured on all clocks to control the outcome of the Grandmaster election. If Priority1s are equal, the next 

criterion is evaluated (clock class) and the criteria are evaluated in succession until a Grandmaster is determined.

To update the PTP settings for the NWE-IP

1. Display the NWE-IP interfaces in DashBoard as outlined in 

To display the NWE-IP interfaces in 

DashBoard

” on page 29.

2. Select the 

Timing

 tab.

The 

Slave Only

 box is selected and cannot be edited.

3. Use the 

Profile

 menu to specify the standard/specification used for PTP. 

4. Use the 

Domain

 field to specify the sub-domain the PTP clock is assigned to.

There can be multiple PTP domains operating concurrently within a network. The domain is a field in all PTP 

message headers. Messaging between entities are segregated by domain (e.g. The NWE-IP is an endpoint 

configured for domain 128 and ignores messages from a neighboring clock configured for domain 127).

5. Use the 

Sync Interval

 field to specify the number of seconds at which synchronization messages are sent from 

the master clock to the specified NET port on the NWE-IP.

6. Use the 

Announce Interval

 field to specify the rate of announce messages that the specified NET port on the 

NWE-IP requests from the master clock during a Unicast session.

7. Use the 

Announce Receipt Timeout

 field to specify the number of seconds the specified NET port on the 

NWE-IP waits for an announce interval message before timing out.

8. Click 

Apply Changes

 to save the new settings.

Summary of Contents for nielsen NWE-IP

Page 1: ...NWE IP User Guide...

Page 2: ...eople that make things happen At Ross our employees are a special group Our employees truly care about doing a great job and delivering a high quality customer experience every day This code of ethics...

Page 3: ...ending Notice The material in this manual is furnished for informational use only It is subject to change without notice and should not be construed as commitment by Ross Video Limited Ross Video Limi...

Page 4: ...ranty and will be repaired without charge for materials or labor within this period See the Warranty and Repair Policy section in this manual for details Environmental Information The equipment may co...

Page 5: ...Fax 1 613 652 4425 Technical Support 1 613 652 4886 After Hours Emergency 1 613 349 0006 E mail Technical Support techsupport rossvideo com E mail General Information solutions rossvideo com Website h...

Page 6: ......

Page 7: ...on Example 17 Basic Physical Setup 17 Configure the Initial Network Settings 18 Configure the Basic Settings of the NWE IP 18 Connect to the 5 1 and Stereo Streams with Different Channel Counts 18 Map...

Page 8: ...AES67 Receiver 40 Mapping the Audio Channels to the AES67 Receiver 41 Routing a Network Stream Group to a Watermark Encoder Channel 43 Enabling the Watermark Encoders 45 Overview 45 Changing the Water...

Page 9: ...ender Interface 69 Network Streams Tab 70 Status Tab 71 Device Setup Tab 71 NMOS Interface 72 Node Tab 72 Technical Specifications 75 Gb1 Specifications 75 NET1 NET2 Specifications 75 USB Port Specifi...

Page 10: ...iv Contents NWE IP User Guide v5 0...

Page 11: ...Configuring the AES67 Receiver outlines the steps required to configuring the AES67 receiver streams on the NWE IP Enabling the Watermark Encoders outlines the steps required to configuring and enabl...

Page 12: ...tacting Ross Video Technical Support At Ross Video we take pride in the quality of our products but if problems occur help is as close as the nearest telephone Our 24 hour Hot Line service ensures you...

Page 13: ...a separate SID for each client Date Time The local time that the creative was encoded The NWE IP uses the Nielsen Audio Encoding System NAES Nielsen Watermarks NW and Critical Band Encoding Technolog...

Page 14: ...rent hardware solution or will be used for a new service If this will be used for a new service or distribution path you will need to obtain a Source Identification SID code from Nielsen The SID is a...

Page 15: ...TE ST 2110 30 Audio AES67 Network Stream Group A network stream group allows you to create a grouping of streams on the network into a unit that can be mapped to a Watermark Encoder channel Network st...

Page 16: ...Surround NWE IP Group 2 Stream 1 Stereo AES67 Input AES67 Output The number of Watermark Encoders is dependent on the number of encoders enabled for the NWE IP AES67 Sender Stream 1 Ch1 AES67 Sender...

Page 17: ...sical Setup The user needs to physically install the NWE IP and ensure the following tasks are performed 1 Physically install the NWE IP in a rack frame Refer to the NWE IP Quick Start Guide 2 Cable t...

Page 18: ...ined in Configuring the PTP Settings on page 43 Connect to the 5 1 and Stereo Streams with Different Channel Counts The 5 1 surround essence includes three streams with two channels where the stereo e...

Page 19: ...ion on the Dell hardware is also displayed Refer to the Dell documentation that accompanied the NWE IP for details on the type of messages this panel displays 4 USB Ports Use each port to connect a ke...

Page 20: ...nnect a keyboard and mouse if you do not have access to a network with DHCP for the initial Ethernet setup or if you have a need to reset your NWE IP static IP address outside of DashBoard 5 NET1 Port...

Page 21: ...right power socket 2 Plug the second IEC connector into left power socket 3 Each AC connector includes a Power Lock which is designed to retain the power cable connector Clip the Power Lock over the s...

Page 22: ...22 Physical Installation NWE IP User Guide v5 0...

Page 23: ...ess Subnet Mask and Gateway for your NWE IP If difficulties or problems are experienced when connecting the NWE IP to a network hub contact your network administrator For More Information on downloadi...

Page 24: ...t the connection is 1Gig If this LED is not lit green verify that the settings of your network switch allow 1Gig communication Connecting Peripheral Devices During initial setup you can optionally con...

Page 25: ...NWE IP User Guide v5 0 Cabling 25 Gb 1 Gb 2 To monitor To keyboard To mouse...

Page 26: ...26 Cabling NWE IP User Guide v5 0...

Page 27: ...k settings of the Gb1 port on the NWE IP DHCP or Static Both methods are described in this section By default the NWE IP ships with a static IP address of 192 168 0 100 Before You Begin Ensure that a...

Page 28: ...in DashBoard 1 From the main tool bar in DashBoard select File New TCP IP DashBoard Connect or openGear Device The New TCP openGear Frame Connection dialog opens 2 In the IP Address field enter the de...

Page 29: ...DashBoard 1 Ensure that you are running DashBoard software version 8 6 0 or higher 2 Launch DashBoard by double clicking its icon on your computer desktop Accessing the NWE IP Interfaces in DashBoard...

Page 30: ...the AES67 Receivers sub node to display its tabs in the DashBoard window 5 Double click the Nielsen Watermark Encoders sub node to display its tabs in the DashBoard window 6 Double click the AES67 Sen...

Page 31: ...5 0 Using DashBoard 31 7 Double click the NMOS sub node to display its tabs in the DashBoard window For More Information on the NWE IP interfaces in DashBoard refer to the chapter DashBoard Interface...

Page 32: ...32 Using DashBoard NWE IP User Guide v5 0...

Page 33: ...ices in your facility and the computer running the DashBoard client After the initial connection is established as outlined in Configuring the Initial Network Settings on page 27 DashBoard is used to...

Page 34: ...ic for the NWE IP To update the NET port settings for the NWE IP 1 Display the Global interface as outlined in To display the NWE IP interfaces in DashBoard on page 29 2 Select the Ethernet tab 3 Sele...

Page 35: ...he NET2 sub tab 4 Click Edit The fields are now editable on the tab 5 Use the Method menu to specify Manual 6 Use the Address field to enter the new IP Address for the NET2 port as provided by your IT...

Page 36: ...36 Updating the Network Settings NWE IP User Guide v5 0...

Page 37: ...terfaces in DashBoard as outlined in To display the NWE IP interfaces in DashBoard on page 29 2 Select the Timing tab The Slave Only box is selected and cannot be edited 3 Use the Profile menu to spec...

Page 38: ...38 Configuring the Timing Settings NWE IP User Guide v5 0...

Page 39: ...global settings 2 Define the Network Stream group s that will provide the AES67 data to be encoded 3 Route each Network Stream group to a Watermark Encoder channel Configure the Global AES67 Receiver...

Page 40: ...der channels as described in Routing a Network Stream Group to a Watermark Encoder Channel on page 43 To add a new network stream group 1 Display the AES67 Receiver interface in DashBoard as outlined...

Page 41: ...relative position of the audio start position as an offset to the reference 9 Repeat steps 3 to 8 for each audio stream you wish to define 10 Click Save to update save your changes and update the lis...

Page 42: ...annel menu to assign a specific stream channel pair to the output channel of the network stream group 5 Click Apply to save your settings To customize the Dolby Surround and Stereo audio channels assi...

Page 43: ...erface in DashBoard as outlined in To display the NWE IP interfaces in DashBoard on page 29 2 Select the Connections tab 3 In the Output Name row of the Outputs area locate the button for the Watermar...

Page 44: ...44 Configuring the AES67 Receiver NWE IP User Guide v5 0...

Page 45: ...ng ensure that you have the following information from Nielsen Encoder Support NAES SID NAES Check Code CBET CSID CBET Check Code Changing the Watermark Encoder Channel Names It is highly recommended...

Page 46: ...or Select this option if the NWE IP is installed in the station or cable network slot of the program distribution chain Program Content Select this option if the NWE IP is installed in the broadcast n...

Page 47: ...ase sensitive and the check characters must be entered in upper case with no spaces between the CSID and check code can be left blank if no CBET encoding is performed for the encoder channel 8 Specify...

Page 48: ...48 Enabling the Watermark Encoders NWE IP User Guide v5 0...

Page 49: ...treams on the NWE IP the default number of audio channels in each stream and how to process the AES67 timestamps These settings are located on the Device Setup tab in the AES67 Sender interface To con...

Page 50: ...stem and other tabs in the DashBoard window 4 Use the Transport IP field to specify the network socket for the data for the session 5 Use the Port field to specify the source port to connect to the st...

Page 51: ...ork Streams tab of the NWE IP locate the row for the network session you want to connect to the downstream device b Click Copy SDP to copy the settings of the NWE IP session c Apply the copied SDP set...

Page 52: ...52 Configuring the AES67 Senders NWE IP User Guide v5 0...

Page 53: ...ation must first be created in DashBoard to show up in the Ember tree under Transmitters If a Sender Session is not configured in DashBoard then these Audio sub groups will contain empty SDP descripto...

Page 54: ...n the NWE IP Now NMOS can be enabled on the NWE IP To configure the NWE IP as a NMOS device 1 Display the NMOS interface in DashBoard as outlined in To display the NWE IP interfaces in DashBoard on pa...

Page 55: ...ough NMOS Next configure the AES67 Sender through NMOS Disabling an AES67 Receiver or Sender session through NMOS will set its IP and port to 0 in DashBoard If the NWE IP is restarted all sessions tha...

Page 56: ...56 Third Party Protocols NWE IP User Guide v5 0...

Page 57: ...u want to upload the file to 10 Verify the NWE IP you want to upload the file to The Error Warning fields indicate any errors such as incompatible software or product type mismatch 11 Click Finish 12...

Page 58: ...58 Upgrading the Software NWE IP User Guide v5 0...

Page 59: ...16 1 summarizes the read only information displayed in the Ethernet tab Table 16 1 Ethernet Tab Item Parameters Description Gb NET MAC Address Specifies the unique Media Access Control MAC Address as...

Page 60: ...nd is not configured for use Edit Click this button to edit the Address Subnet Mask gateway and Method fields for the specified port Apply Click this button to apply the new settings to the specified...

Page 61: ...on where a value of 1 is the highest priority 255 is the lowest priority This menu is applicable when the Slave Only box is not selected Priority 2 Assigns the secondary priority level to the NWE IP d...

Page 62: ...e Master in nanoseconds GM Present read only True Indicates a Grandmaster is available False Indicates a Grandmaster is unavailable GM Identity read only Reports the ID number assigned to the Grandmas...

Page 63: ...the stream group The default value is 2 Paste SDP To session name Applies the settings copied from a device that supports the Session Description Protocol SDP to the specified session of the selected...

Page 64: ...nd monitor the status of the output signals Table 16 5 summarizes the buttons menus and fields available in the Output area of the Connections tab Target Type Stereo Specifies that the audio stream tr...

Page 65: ...is present but the alarm is disabled on the Alarm Enable tab Network Delay Too Big Yellow The link offset selected by the user is smaller than the propagation delay of the network No packets received...

Page 66: ...d by the user is smaller than the propagation delay of the network No Packet Received Yellow The configured destination IP stream s is not receiving any packets stream might not be on the network or e...

Page 67: ...ates the sample rate of the audio signal Packet Time Indicates the offset to the audio streams Default Channels Specifies the default number of audio channel available for configuration CODEC Indicate...

Page 68: ...r case CBET CSID Specifies the Critical Band Encoding Technology CBET Source Identification Number SID that is assigned by Nielsen to this NWE IP This field is case sensitive and your must enter the c...

Page 69: ...rmarker Name text Indicates the unique identifier for the specific watermark output stream Table 16 10 Device Setup Tab Item Parameters Description Watermark Type NAES CBET The NWE IP uses both NAES a...

Page 70: ...r the Sender session Copy SDP session name Copies the Session Description Protocol SDP settings of the specified NWE IP session These settings can then be applied to a downstream device to establish c...

Page 71: ...er for the specified stream Buffer Underrun Specifies the number of under runs of the sender buffer Packets Lost The number of packets lost by the specified stream Session Name text Reports the unique...

Page 72: ...AES67 Receiver stream Processed Timestamp The NWE IP replaced the original timestamp with the current PTP timestamp Clock Reference NET Indicates the physical port on the NWE IP that is used as the ti...

Page 73: ...65535 Specifies the port on which the Node API is running on Domain text Specifies which domain to browse for services When this field is blank the NWE IP uses the default domain Specify local to exp...

Page 74: ...74 DashBoard Interface Overview NWE IP User Guide v5 0...

Page 75: ...cifications Gb1 Item Specifications Standards Accommodated 1000 BASE T Connector Type RJ45 Table 17 2 Technical Specifications NET1 Item Specifications Standards Accommodated 1000 BASE T Connector Typ...

Page 76: ...76 Technical Specifications NWE IP User Guide v5 0...

Page 77: ...t to repair or replace this piece of equipment with a unit of equal or superior performance characteristics Should you find that this NWE IP has failed after your warranty period has expired we will r...

Page 78: ...78 Service Information NWE IP User Guide v5 0...

Page 79: ...assigned to local broadcast affiliates or to cable network content Typically it specifies that your facility is the final station or network in the program distribution chain LTC and Timecode refer to...

Page 80: ...80 Glossary NWE IP User Guide v5 0...

Reviews: