Chapter 1 Introduction
Accura 2300/2350 User Guide
Page 22
ⓒ
2011 Rootech Inc. All Rights Reserved
TM-1P-60
Accura 2350-1P-125A-60 connection
134g
TM-1P-50L
Accura 2350-1P-100A-50 connection
121g
TM-1P-50
Accura 2350-1P-60A-50 connection
88g
TM-1P-105-LB
7
Accura 2350-1P-250A-105 connection
246g
TM-1P-60-LB
7
Accura 2350-1P-125A-60 connection
142g
TM-1P-50L-LB
7
Accura 2350-1P-100A-50 connection
128g
TM-1P-50-LB
7
Accura 2350-1P-60A-50 connection
96g
Mounting wing
Accura 2350-3PSC-CT5A-90
-
4g
1. Packaged with device. Core conductor of 6C telephone line should be minimum 0.128mm
2
[26 AWG]. It is recommended
that distance from power line is 5mm or more so that interference caused by noisy power line will not occur.
2. Accura 2300 displays only measurements of one Accura 2350 selected. Refer to “Chapter 4>Display Mode>Accura 2350
Module ID Selection”.
3. When RS485 option is selected, digital I/O terminal is replaced with RS-485 communication terminal. See ordering
information.
4. It is not for fire-watching, but for reference only. A temperature sensor is mounted on the side of Accura 2300.
5. If rating current exceeds 250A, Accura 2350-3P-CT5A-75 or Accura 2350-3PSC-CT5A-90 using external CT[secondary
rating 5A] should be used.
6. Split-core single-phase single-hole power measuring modules can be used in three-phases by installing one module per
phase [A, B, C] and grouping them. In the case of three-phase three-wire connection, it is possible to measure three-phases
only by installing two modules on phase A and phase C.
7. LB: Long Busbar
8. It is the weight excluding the mounting wing.
Special-Purpose Module
Accura 2350 modules with special functions besides power measuring module are as follows. For details on
these special-purpose modules, refer to UserGuide for each module.
Module
Model
Description
GAS[GAS]
Accura 2350-GAS
Measurement of gas density of surroundings
GW[Gateway]
Accura 2350-GW
Data collection for peripheral devices supporting RS-485
communication
TEMP[Temperature]
Accura 2350-TEMP
Simultaneous measurement of internal and external temperature
[based on temperature measuring module installation surface]
DO[Digital Output]
Accura 2350-DO
Provides digital output which is able to be controlled in remote and
from Accura 2300.
IDC[DC Current Input]
Accura 2350-IDC
Analog DC current input [-20mA to 20mA]
VDC[DC Voltage Input]
Accura 2350-VDC
Analog DC voltage input [-50V to 50V]
DCM[DC Voltage/Current]
Accura 2350-DCM
Analog DC voltage/current[50V/80A]