Manual
Double Sheet Detector R100 I100
for pairs of sensors
B0003308 / 1.4 /
13.02.2013
Start-up
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
29
6 Start-up
Pos: 25 /Doppelblech/Geräte/R1002/6 Inbetriebnahme / Bedienung/Bedienelemente und Anzeigen @ 0\mod_1184848094000_501.doc @ 4115 @
6.1
Keys and indicators
The control unit has three operating keys, which provide for easy adjustment.
Adjustment is required upon commissioning and change of material.
Description
fault
power
2 sheet
1 sheet
0 sheet
1 LCD display
2 Operating keys
3 LEDs for condition of unit
FAULT
malfunction
POWER power supply
4 LEDs for switch conditions
2-Sheet
1-Sheet
0-Sheet
Fig. 17: Controls and indications
6.2
Allocation and function of keys
The functions of the 3 operating keys are variable, as will be shown in the lower line of the display.
For example, the operator can change from the
measuring mode into the setup mode with the key
“setup”.
Fig. 18: Indication of key allocation
R100structure.bmp
Note!
If a function causes a fault, a fault number is indicated and the yellow
LED "FAULT" lights.
The error condition can be confirmed with the right "ENTER" key.
Otherwise the system changes to the measuring mode after approx 5
seconds. The “FAULT” LED will, however, go off only if upon a new
attempt the requested function is fault free.
If a function consists of several steps, which are not completely
executed, the system automatically changes back to the original
measuring mode after approx. 5 seconds.
Dummy I100-2.jpg
Pos: 26 /Doppelblech/Geräte/R1002/6 Inbetriebnahme / Bedienung/Belegung und Funktion der Tasten @ 0\mod_1184849242203_501.doc @ 4130 @
2
1
4
3