![Roland Double Sheet Detector I100 Manual Download Page 10](http://html1.mh-extra.com/html/roland/double-sheet-detector-i100/double-sheet-detector-i100_manual_1481827010.webp)
Manual
Double Sheet Detector R100 I100
for pairs of sensors
Technical data
B0003308 / 1.4 / 13.02.2013
10
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Description
1 Screw fitting M16
for control cable
Wrench size 19 mm
2 Screw fitting M12
for sensor cable (transmitter)
Wrench size 15 mm
3 Screw fitting M12
for sensor cable (receiver)
Wrench size 15 mm
120
114
90,5
13
5
154
14
8
16
0
35
38
3
1
2
90
30
40
M16×1,5
SW 19
M12×1,5
SW 15
M12×1,5
SW 15
Deckel / Lid
63
fault
power
2 sheet
1 sheet
0 sheet
4,2 Ø
Fig. 2: Dimensions of I100-IP65 (in protective enclosure IP65)
I100 in multibox IP65.wmf