Step 3
Press the key “value“.
Pressing the key “value“ enables editing of the thresholds for L and U.
Editing is done with the absolute values, based on the current
measurement value.
Fig. 25: Enabling editing
R100TCha.bmp
Step 4
The sign “!“ before “L“ indicates that the value L can be changed.
The key “-“ decreases the L value,
the key “+“ increases the value.
Fig. 26: Changing the lower threshold value L
R100TChangeHandvalue.bmp
Step 5
Select the parameter U with the key “next“.
The sign “!” closes up to the “U“.
The key “-“ decreases the L value,
the key “+“ increases the value.
Fig. 27: Selecting the upper threshold value U and changing the value
R100TChangeHandNext.bmp
Step 6
Closing the setting:
With the key „exit“ the values are stored. The system changes over to the measurement mode. The
changed thresholds will be used from now on.
Pos: 32 /Doppelblech/Geräte/R1002/6 Inbetriebnahme / Bedienung/Teach-In mit geänderten Schwellwerten @ 0\mod_1184850230968_501.doc @ 4145 @