Electrical installation
B0003308 / 1.4 / 13.02.2013
26
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
5.3
Connections at I100-S
1
2
3
1 Supply socket
2 Sensor socket f. receiver
3 Sensor socket f.
transmitter
Fig. 13: Connections I100-S
Supply socket (pos. 1)
Socket at unit
Supplier / types / remarks
Enclosure HAN 3A, EMI-type, metrical
7-pin insert with PE, Pin contacts at control unit
Harting and others
Pin1
+24V DC
Internal Pin 2
Pin 2
common / GND
Internal Pin 3
Pin 3
Teach-In
Internal Pin 4
Pin 4
2-sheet
Internal Pin 5
Pin 5
1-sheet
Internal Pin 6
Pin 6
0-sheet
Internal Pin 7
Pin 7
+24V DC f. I/O
Internal Pin 8
view onto contacts
Pin 8
PE
Internal Pin 1
The associated cable plug (contacts) is not within the scope of delivery, it must be ordered separately under S0003515.
See also chapter ”Order data“.
Sensor socket f. receiver (pos. 2)
Socket at unit
Supplier / types / remarks
M12, 2-pin, B-coded,
female connector at control unit
Binder Type 713 and others
Pin 1
+V
in
Internal Pin 10
Wire colour: brown
Pin 2
-V
in
Internal Pin 11
Wire colour: white
3
1
view onto contacts
Enclosure
Shield
Internal Pin 14
transparent / green-yellow
Sensor socket f. transmitter (pos. 3)
Socket at unit
Supplier / types / remarks
M12, 3-pin, B-coded,
female connector at control unit
Binder Type 713 and others
Pin 1
+12V
Internal Pin 15
Wire colour: brown
Pin 2
-12V
Internal Pin 17
Wire colour: white
Pin 3
common / GND
Internal Pin 16
Wire colour: green
3
2
1
view onto contacts
Shield
Internal Pin 18
transparent / green-yellow
Fig. 14: sockets I100-S