Sample Application
R&S
®
DVMS4
30
Getting Started 2113.7625.02 ─ 10
● In the "Locked" state, the value is "0".
Under "SITE", the LED symbol is green. At the rear panel, the LED correspond-
ing to the TS IN input switches to green.
● In the "Unlocked" state, the value is > 0, continuously incrementing (every sec-
ond).
Under "SITE", the LED symbol shows the icon for TS synch loss. At the rear
panel, the LED corresponding to the TS IN input switches to yellow.
The following measurements can only be performed, if TS synchronization is in the
"Locked" state.
6.5
Performing the Measurement
Since the measurement results strongly depend on the content of the TS input signal,
the following examples use basic parameters and measurements valid for all kind of
MPEG2 TS signals.
6.5.1
Checking the Gross Bit Rate of the Connected TS
1. In the toolbar, click "View Selector".
2. In the "View Selector" dialog, click the icon for the bit rate measurement.
Performing the Measurement