Interfaces and Connectors
R&S
®
DVMS4
22
Getting Started 2113.7625.02 ─ 10
●
LED green: Input is used for monitoring. Synchronization state is valid for the trans-
port stream signal.
●
LED yellow: Input is used for monitoring but synchronization cannot be achieved.
TS OUT
This BNC socket provides an MPEG2 transport stream signal conforming to the
DVB
‑
ASI (EN 50083
‑
9 (2002)) interface standard.
The interface is used as a loop output for any transport stream input signal available.
To select the input, in the toolbar, click "Instrument Configuration" and then select "Sig-
nal Interface". See the user manual or help system.
An LED indicates the TS OUT status:
●
LED off: Output is not used.
●
LED blue: Output is used as loop output.
3.2.9
TS/IP Interface Module (R&S
DVMS-B40)
The TS/IP module is optional (R&S
DVMS
‑
B40).
Figure 3-8: TS/IP interface module
TS IN/OUT 1 and TS IN/OUT 2
Each of these two BNC sockets is used either as input or output for MPEG2 transport
streams. If used as an input, feed in an MPEG2 transport stream signal conforming to
the DVB
‑
ASI (EN 50083
‑
9 (2002)) or SMPTE (SMPTE310M) interface standards. If
used as an output, this socket provides an MPEG2 transport stream signal conforming
to the DVB
‑
ASI (EN 50083
‑
9 (2002)) interface standard. The output can be used as a
loop output for any transport stream input signal available.
To select the input or output, in the toolbar, click "Instrument Configuration" and then
select "Signal Interface". See the user manual or help system.
The status of the connectors is indicated by LEDs. Before showing a new status, each
LED holds the status for at least one second, if the status is not "off" or "flashing".
●
LED off: Connector is not used.
●
LED blue: Connector is used as a loop output for any MPEG2 transport stream
input signal.
●
LED green: Connector is used as an input for monitoring. Synchronization state is
valid for the transport stream signal.
Rear Panel